IC697PWR711

GE Fanuc | 9070 | GE Fanuc 90-70 PLC

IC697PWR711 Image

IC697PWR711

Same Day - Free Shipping

  • Manufacturer: GE Fanuc
  • Description: Power Supply, 120/240 Vac,125VDC, 100 Watts
  • Weight: 4 lbs :: ≈ 2 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC697PWR711 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -AA, -BA, -BB, -BC, -CD, -DD, -DE, -EE, -EG, -EH,

Product Manual Excerpt

120/240 VAC or 125 VDC (IC697PWR711/713) datasheet GFK-1448B This data sheet describes version H (IC697PWR711H/713H), or later versions of this power supply. F or a description of version G (IC697PWR711G/713G), and earlier versions see data sheet GFK-0392G. Features Operation from 120 VAC, 240 VAC, or 125 VDC Three output voltages, 100 watts total +5 VDC output up to 20 amps +12 VDC output up to 2 amps -12 VDC output up to 1 amp Slide-in rack mount construction Electronic short circuit overcurrent protection Two rack operation from a single power supply Power Factor correction for AC operation Jumper for overvoltage protection devices Functions The 100 Watt Power Supply Module is a rack-mounted unit that plugs directly into a 48-pin backplanemounted connector in the leftmost slot in the rack. It provides +5 volt, +12 volt and -12 volt power, and logic level sequencing signals to the backplane. This power supply may be used either in a single rack application, or may also be used to provide power to a second rack if the total load is within the supply rating. Interconnection to the second rack is through a prewired cable (see the ordering instructions on the last page of this data sheet). + 125 VDC OFF a47113 ON INPUT OUTPUT INPUT POWER SUPPLY MODULE Torque 12 in-lb (1.3 N-m) Conductors 120/240VAC 1.4A/0.7A 50/60HZ 125 VDC 1.4A +5V AT 20A 100 WATTS TOTAL Replace with same type and rating 2A/250V +12 AT 2A 12 AT 1A WARNING: DO NOT DISCONNECT WHILE CIRCUIT IS ALIVE UNLESS AREA IS KNOWN TO BE NONHAZARDOUS POWER SUPPLY WARNING Even if the power supply is switched off, hazardous voltages from user field wiring may still be present on the I/O terminal boards as well as on the power supply terminal board. Care should be taken when handling the power supply and I/O modules as well as any wiring connected to them in order to prevent personal injury. WARNING EXPLOSION HAZARD WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES. ALIMENTACION ELECTRICA ATENCION Incluso si la alimentacion electrica esta desconectada, voltajes peligrosos provenientes del cableado externo pueden estar presentes en los terminales de entrada/salida (I/O), asi como en los terminales de la tarjeta impresa de la fuente de poder. Debe prestarse atencion en el manejo de la fuente de poder, en el manejo de los modulos de entrada/ salida (I/O), y en el manejo de cualquier cable conectado a la fuente o a los modulos para evitar dan~os personales. ADVERTENCIA RIESGO DE EXPLOSION CUANDO ESTA EN ZONAS PELIGROSAS, DESCONECTAR LA POTENCIA ANTES DE REEMPLAZAR O INSTALAR LOS MODULOS. L1 N 120/240VAC GFK-1448B Power Supply Module, 100W, 120/240 VAC or 125 VDC 2 Power Supplies August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 10-2 The power supply output will ride through at least one input line cycle with a total loss of input power at full load. Protection is provided for overcurrent and overvoltage fault conditions. Operation of the Power Supply This Power Supply module can operate from either 120 VAC or 240 VAC nominal inputs. It will also operate from a nominal 125 VDC source. The specified range of operation is from 90 VAC to 264 VAC, and from 100 VDC to 150 VDC. For continuous operation (greater than one hour) at low line voltages and high temperatures, some power derating must be applied. Refer to the following figure to determine the normal operating range for specific applications. Normal operating range is shown by the shaded area of the graph for 60 C (140 F) installations. Operation in the non-shaded region for specific applications must be limited to <1 hour. Reducing the maximum operating temperature to 55 C (131 F) will increase the normal operating range as indicated on the graph. Active power factor correction circuits in this supply maintain a near unity power factor for AC inputs, which eliminates the need for oversized circuit breakers and wiring. This circuitry also limits the half cycle peak inrush currents to a low value. 55 C 60 C 50 C 90 100 110 120 130 100 95 90 85 LIMITED OPERATING RANGE (< 1 HOUR ) 264 MAXIMUM TOTAL OUTPUT POWER (WATTS) INPUT VOLTAGE (VRMS OR VDC) NORMAL OPERATING RANGE FOR CONTINUOUS OPERATION (>1 HOUR) IN MINIMUM SIZE ENCLOSURE WITH NO FORCED AIR CIRCULATION. VIN 95 105 Figure 1. Power Derating for Low Line Voltages Overvoltage Protection An electronic shutdown circuit protects against voltages exceeding 6.2 volts. A back-up voltage clamp is provided to protect against sustained overvoltage conditions due to either external influences or internal faults. Overvoltage due to internal faults may cause the fuse to open. For short term overvoltage conditions, normal operation will resume when the cause is removed. Overcurrent Protection An electronic current limit is provided on each of the three outputs. An overload on any output will cause the voltage to collapse and may cause the other output voltages to collapse. Normal operation will resume after removal of the overload. Some component cooling time may be required before normal operation resumes. 3 Power Supply Module, 100W, 120/240 VAC or 125 VDC GFK-1448B Power Supplies August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 10-3 Dual Rack Operation A single power supply can provide power for two racks under the following conditions: Only 5 volt power is required in the second rack, and the total power required by both racks is within the capability of the supply. The current drawn by the second rack is less than 5.2 amperes. The two racks must be mounted in close proximity as limited by the available 3-foot connecting cable. The connecting cable used for dual rack operation is listed in Table 2, Ordering Information. This cable carries the +5 volts power bus as well as the power sequencing signals. It uses a 9-pin D-type connector which connects directly to the backplane through an opening in the rack frame. Note that the cable carries power and power sequencing signals only. Inter-rack communication and bus interface modules must be provided separately. See the applicable Programmable Controller Installation Manual. for application information. FACE TWO RACK POWER CABLE INSTALL CABLE SO THAT THE INDICATED END IS SUPPLYING POWER Figure 2. Dual Rack Configuration Timing Diagram The timing diagram below shows the relationship of the ac input power to the dc outputs and to the two system signals generated by the power supply: ACFAIL and SYSRESET. The 5VSTBY output may be used for user battery backup schemes as shown. On application of power, the ACFAIL signal goes false soon after the 5 volt bus is within specification. The system is held in the Reset state by SYSRESET for at least 200 milliseconds after 5 volt power is available (during this time, outputs are forced off). If AC input power is interrupted, the 5 volt bus will remain within specifications for at least one cycle. The system is then given an additional 5 milliseconds to complete an orderly shutdown before SYSRESET stops all processing. 5ms MIN 21 ms MIN 200 ms MIN OUTPUT 4.9V 4.9V POWER SYSRESET ACFAIL 26.5ms MIN 1 CYCLE INPUT POWER ON AC OFF ON OFF 5VSTBY 2 1 2 1 5VSTBY CONNECTED TO POWER SUPPLY 5VDC 2 5VSTBY DISCONNECTED FROM POWER SUPPLY 5VDC BY A TRANSISTOR TO ALLOW CONNECTION OF USER BATTERY SOURCE. a42132 50ms MIN | } Figure 3. Timing Diagram Note Input power interruptions which exceed the power supply holdup time (21 milliseconds minimum) will result in a complete power down/power up cycle of ACFAIL and SYSRESET. Mounting This Power Supply is a plug-in module that is installed in the leftmost slot of any standard IC697 rack or VME Integrator s rack. For additional installation information, refer to GFK-1179, Installation Guidelines for Conformance to Standards, shipped with the PLC programming software. GFK-1448B Power Supply Module, 100W, 120/240 VAC or 125 VDC 4 Power Supplies August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 10-4 Power Supply Door The power supply door can easily be opened by grasping the upper left corner of the door with your right thumb or a fingernail and gently pulling the door towards you. Use care when opening the door since pulling from the bottom can cause the hinge or the door to break. Field Wiring Connections The power input terminal board has four terminals. The top two (L1 and N) are for 120/240 VAC or 125 VDC input power connections; the third and fourth terminals are for ground and overvoltage protection device connections, respectively. Power input connections should be made with copper AWG #16 (1.3 mm2 ) wire rated for 75 C (167 F). Each terminal can accept solid or stranded wires, but the wires into any given terminal should be the same type and size. It is recommended that the ground terminal on the power supply be connected to the GND terminal on the rack and to earth using copper AWG #12 (3.3 mm2 ) wire rated for 75 C (167 F) to ensure adequate grounding. Use of a nut and star washer for each wire on the ground terminal is recommended. IC697 RACK STUD (8 32) #12 (3.3 mm2) a47111 INPUT 75 C Copper Torque 12 in-lb (1.3 N-m) Conductors Replace with same type and rating 2A/250V L1 + 125 VDC N 120/240VAC EARTH GROUND WARNING: DO NOT DISCONNECT WHILE CIRCUIT IS ALIVE UNLESS AREA IS KNOWN TO BE NONHAZARDOUS CONNECT JUMPER STRAP BETWEEN TERMINALS 3 and 4 FOR OVERVOLTAGE PROTECTION DEVICES. H N G Figure 4. Terminal Board Connections for IC697PWR711/713, Versions H and Later Overvoltage Protection Devices The overvoltage protection devices (see Figure 5) for this power supply are connected internally to terminal 4 (bottom terminal) on the input terminal board. This pin is normally connected to frame ground (terminal 3) with the supplied jumper strap which is installed at the factory. If overvoltage protection is not required or is supplied upstream, this feature can be disabled by leaving terminal 4 unconnected by removing the jumper strap. If you want to Hi-pot test this supply, overvoltage protection must be disabled during the test by removing the terminal board strap. Re-enable overvoltage protection after testing by reinstalling the strap. 1 2 3 4 a47106 Jumper Strap Connects Overvoltage Protection Devices to Frame Ground Screw Terminals on Terminal Board Frame Ground Figure 5. Overvoltage Protection Devices and Jumper System Noise Immunity Two easy steps must be taken to properly ground the programmable controller system to reduce the possibility of errors due to electrical noise (see Figure 5). 1. The Ground terminal on the power supply must be connected to the GND terminal on either side of the rack using AWG #12 (3.3 mm2 ) wire. The Ground terminal should be also be connected to incoming safety ground. 2. The GND terminal on the rack must be connected to a good earth ground. 5 Power Supply Module, 100W, 120/240 VAC or 125 VDC GFK-1448B Power Supplies August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 10-5 Table 1. Specifications FOR IC697PWR711/713 (Version H and Later) Nominal Rated Voltage: 120/240 VAC, or 125 VDC Input Voltage Range: AC Input DC Input 90 to 264 VAC, 47 to 63 Hz 100 to 150 VDC Input Power: 135 watts (typical), 160 watts (maximum) Input Half Cycle Peak Inrush 3 amps (typical) Power Factor > .93 Output Power: 100 watts maximum (total for all 3 outputs) Output Voltage: +5 VDC: 4.90 to 5.25 volts (5.07 volts nominal) +12 VDC: 11.75 to 12.6 volts -12 VDC: -12.6 to -11.75 volts Protective Limits - Overvoltage Limit: +5 VDC Output: 5.7 to 6.7 volts Overcurrent Limit: +5 VDC output: 21A (typical) +12 VDC output: 3.5A (typical) -12 VDC output: 1.6A (typical) Holdup Time: 21 milliseconds minimum (from loss of AC input) Environmental - Operating Temperature: 0 C to 60 C (32 to 140 F) operating 40 C to +85 C (-40 to +185 F) storage Refer to data sheet GFK-0867B, or later for product standards and general specifications. Derate for continuous low input voltage, (see Figure 1) Table 2. Ordering Information Description Catalog Number Power Supply, 120/240 Volts AC, or 125 Volts DC 100 Watts (with jumper for overvoltage protection devices version H, or later version) IC697PWR711/713 Power Supply Extension Cable (includes cable and faceplate for empty power supply slot in second rack). IC697CBL700 Note: For Low Temperature Testing option please consult the factory for price and availabilit

Need To Order A Specific Revision?

Give us a call at 1-800-360-6802 or 1-919-535-3180. We can help you with your Revision specific needs.


UPS Ground shipping is always FREE!


What is New Surplus?

These “New Surplus” units are a great cost saving alternative. This product is in the original manufacturer’s packaging with all sub-assemblies and documentation. Comes with a PLC Distribution Factory & Supply 3-year warranty.


UPS Ground shipping is always FREE!


What is Surplus New?

Surplus New - New unused and includes all sub-assemblies and documentation. Product may ship in manufacturer or PLC Distribution Factory & Supply packaging and includes a PLC Distribution Factory & Supply 3 Year Warranty.


UPS Ground shipping is always FREE!


What is Reconditioned?

Reconditioned products from PLC Distribution Factory & Supply are a cost-effective alternative to new and obsoleted PLC products. Every part is reconditioned down to the circuit board level. All parts are thoroughly inspected and hand-cleaned before being functionally tested in a fully configured system.


Our Reconditioned Products always come with a PLC Distribution Factory & Supply 2-Year Warranty.

UPS Ground shipping is always FREE!


110% PRICE MATCH GUARANTEE


We stand behind our prices with a 110% price match guarantee. If you buy a part from us and, within seven days of purchase, find that part advertised on an authorized distributor's website for less, simply contact us and give us a link to the lower advertised price and we'll refund you 110% of the difference between your purchase price and the advertised lower price. The part must be in-stock for immediate shipment and be in similar condition. All pricing must be displayed without signing in.

Repair Service


3-5 Days for most repairs. 24 hour repair upon request at no extra charge. If part is unrepairable, we will exchange with a working unit or return unrepaired.