IC697MDL340

GE Fanuc | 9070 | GE Fanuc 90-70 PLC

IC697MDL340 Image

IC697MDL340

Same Day - Free Shipping

  • Manufacturer: GE Fanuc
  • Description: (16) 120 Volts ac Output, 2 Amp
  • Weight: 4 lbs :: ≈ 2 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC697MDL340 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -AA, -BA, -BB, -BC, -CD, -DD, -DE, -EE, -EG, -EH,

Product Manual Excerpt

16 Points - Four isolated groups of 4 points each 2 amp capacity per point High inrush capacity (10x rated current) Functions The 120 Volt AC 2 Amp Output Module provides 16 output points in four isolated groups of four points each. This allows each group of four points to be used on different phases of the AC supply. Each group of four outputs is individually fused with a 10 amp fuse. The module provides a high degree of inrush current which makes the outputs suitable for a wide range of inductive and incandescent loads. The module will pick up most size 4 contactors. LED indicators which give the ON/OFF status of each point on the logic(PLC) side of the circuit as well as an LED to indicate the status of the fuses are located together at the top of the module. The module is mechanically keyed to ensure correct replacement with a similar type in the field. I/O references are user configurable without the use of DIP switches or jumpers on the module. Configuration is done using the configuration function of the MS-DOS or Windows programming software running on Windows 95 or Windows NT over Ethernet TCP/IP or through the SNP port. The Programming Software configuration function is installed on the programming device. The programming device can be an IBM) XT, AT, PS/2) or compatible Personal Computer. IBM and PS/2 are registered trademarks of International Business Machines Corporation. MS-DOS, Windows, Windows 95, and Windows NT are registered trademarks of Microsoft Corporation. GFK-0082H 120 Volt AC 2 Amp, 16-Point Output Module 2 Discrete Output Modules August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 50-2 Operation of the 120 Volt AC 2 AMP Output Module OPTO ISOLATOR COMMON OPTO ISOLATOR OUTPUT DRIVER LOAD TO OTHER OUTPUTS FIELD CONNECTIONS MODULE SYSTEM BACKPLANE INTERFACE a42138 FUSE OPEN FUSE DETECTOR LED ~ Figure 1. Block Diagram for IC697MDL340 Output Characteristics The 120 Volt AC 2 Amp Output Module is compatible with a wide variety of load devices, such as: Solenoids and motor starters Indicators The rating of 2 amps per point applies to the longterm capacity of each point. Because of overall heat dissipation within the module, the maximum current capacity for each group of four outputs is limited to 4 amperes. Each output on this module is capable of transiently conducting a surge current which is much greater than its long-term current rating. The rate at which such surges can be repeated depends on the current rating of the device and the duty cycle (percent of time the device is ON).For typical incandescent devices operating at a 50% duty cycle, the following repetition rates apply. Steady-state Repetition Rate Fault Mode Selection The module can be configured from the programmer so that output points assume one of two states in response to certain operating or default conditions. Maintain existing output state Turn outputs OFF This is explained in more detail in the programming manual. Fusing Each group of 4 outputs is fused with a 10 amp fuse. Replace with either of the following types: 3AG - 10 amp, 250V, Fast Acting Metric 5 x 20 mm - 10 amp, 250V, Fast Acting 3 120 Volt AC 2 Amp, 16-Point Output Module GFK-0082H Discrete Output Modules August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 50-3 Module Mechanical Keying This module includes a mechanical key that prevents inadvertent substitution of one module type for another in a given slot. The key fits a uniquely shaped area on the board below the connector. The key is included with each module. When the module is first installed, the key latches onto the backplane center rail. When the module is extracted, the key remains in the center rail, configuring the slot to accept only identical module types. If it is necessary to change the module location in the rack after the key has been latched onto the center rail of the rack, the key can be removed by pushing it upward to unhook the latch while pulling it off the rail. It may then be reinserted onto the module and the module inserted into the rack in the desired location. Note: only the power supply can be placed in the leftmost rack position. Field Wiring The module is wired as shown. Since each group of four outputs is isolated from the others, a wire from the power source to the power input terminals for each group is required (power input terminals for each group are not connected inside the module). The detachable field wiring terminal board will accept wire sizes from AWG #22 (0.36 mm2) through AWG #14 (2.10 mm2). Two wires may be terminated on a given lug if both wires are the same size. There is room for a bundle of forty AWG #14 (2.10 mm2) wires to be routed out through the terminal board cavity. The wire bundle can be secured to the terminal board by passing a cable tie through a cleat located at the lower corner of the terminal board. TERMINALS Figure 2. Field Wiring Connections GFK-0082H 120 Volt AC 2 Amp, 16-Point Output Module 4 Discrete Output Modules August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 50-4 Recommended Field Wiring Procedures The following procedures are recommended when connecting field wiring to the detachable terminal board on this input module. Module features referenced in the following procedures which are common to all IC697 I/O modules are illustrated in the following figure. Figure 3. I/O Module Features 1. Turn off power before removing or installing terminal boards. Open the hinged door on the module to access a jackscrew which holds the terminal board securely in place. The detachable field wiring terminal board can now be removed from the module by turning the jackscrew counter-clockwise until it is fully disengaged. 2. To remove the terminal board, grasp the top of the terminal board and swing it outward as shown in Figure 4. Caution Do not use the hinged door to remove the terminal board. The hinged door could be damaged if this is done. 3. The terminal board is designed to accept wire sizes from AWG #22 (0.36 mm) through AWG #14 (2.10 mm). It is important that when using AWG #14 (2.10 mm2) wire for wiring all points, that a maximum insulation diameter of .135 inch (3.43mm) not be exceeded. To ensure proper connection, two wires may be terminated on any one terminal only if both wires are the same size. 4. The terminal board is designed to accept a maximum of (40) AWG #14 (2.10 mm2)wires. If AWG #14 (2.10 mm2) wires are to be used, then wire markers should be placed at least 8 inches (203 mm) from termination end to provide sufficient space for the hinged door to close. 5 120 Volt AC 2 Amp, 16-Point Output Module GFK-0082H Discrete Output Modules August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 50-5 JACKSCREW a43747 WIRE BUNDLE CABLE TIE CLEAT DO NOT PULL ON DOOR Figure 4. Removal of I/O Terminal Board 5. After completing connections to all modules in a rack, the wire bundle must be secured. To ensure that the wire bundle is secured properly, it is recommended that a cable tie be wrapped around the wire bundle and tightly secured through the cable tie cleat located at the lower right corner of the terminal board. For extremely large wire bundles, additional cable ties should be used. 6. A door label insert is included with each module to indicate circuit wiring information and provide space to record user circuit wiring identification. A slot is provided on the hinged door to allow for insertion of this label. If the label is difficult to insert, crease the scored edge before insertion. The outside label has a color coded stripe to allow quick identification of the module voltage type (blue: low voltage; red: high voltage). 7. After field wiring is completed, the terminal board should be securely fastened to the rack by inserting the terminal board strap (attached to each module) into the small rectangular slots in the bottom card guide grill on the rack. This strap not only secures the terminal board to the rack, it also provides a way of identifying the wired terminal board with its correct mating rack slot location. 8. For adequate module ventilation, it is recommended that at least a 6 inch (152mm) clearance be allowed above and below the rack grill. Wire bundles should not obstruct the rack grill work. Removing an I/O Module The instructions below should be followed when removing an I/O module from its slot in a rack. Grasp the board firmly at the top and bottom of the board cover with your thumbs on the front of the cover and your fingers on the plastic clips on the back of the cover. Squeeze the rack clips on the back of the cover with your fingers to disengage the clip from the rack rail and pull the board firmly to remove it from the backplane connector. Slide the board along the card guide and remove it from the rack

Need To Order A Specific Revision?

Give us a call at 1-800-360-6802 or 1-919-535-3180. We can help you with your Revision specific needs.


UPS Ground shipping is always FREE!


What is New Surplus?

These “New Surplus” units are a great cost saving alternative. This product is in the original manufacturer’s packaging with all sub-assemblies and documentation. Comes with a PLC Distribution Factory & Supply 3-year warranty.


UPS Ground shipping is always FREE!


What is Surplus New?

Surplus New - New unused and includes all sub-assemblies and documentation. Product may ship in manufacturer or PLC Distribution Factory & Supply packaging and includes a PLC Distribution Factory & Supply 3 Year Warranty.


UPS Ground shipping is always FREE!


What is Reconditioned?

Reconditioned products from PLC Distribution Factory & Supply are a cost-effective alternative to new and obsoleted PLC products. Every part is reconditioned down to the circuit board level. All parts are thoroughly inspected and hand-cleaned before being functionally tested in a fully configured system.


Our Reconditioned Products always come with a PLC Distribution Factory & Supply 2-Year Warranty.

UPS Ground shipping is always FREE!


110% PRICE MATCH GUARANTEE


We stand behind our prices with a 110% price match guarantee. If you buy a part from us and, within seven days of purchase, find that part advertised on an authorized distributor's website for less, simply contact us and give us a link to the lower advertised price and we'll refund you 110% of the difference between your purchase price and the advertised lower price. The part must be in-stock for immediate shipment and be in similar condition. All pricing must be displayed without signing in.

Repair Service


3-5 Days for most repairs. 24 hour repair upon request at no extra charge. If part is unrepairable, we will exchange with a working unit or return unrepaired.