IC697MDL250

GE Fanuc | 9070 | GE Fanuc 90-70 PLC

IC697MDL250 Image

IC697MDL250

Same Day - Free Shipping

  • Manufacturer: GE Fanuc
  • Description: 120 Volts ac Input (32)
  • Weight: 4 lbs :: ≈ 2 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC697MDL250 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, -, -AA, -BA, -BB, -BC, -CD, -DD, -DE, -EE, -EG, -EH,

Product Manual Excerpt

32 Points - Four isolated groups of 8 points each 20 ms input filter Proximity switch compatible Functions The 120 volt AC Input module for the programmable controller provides 32 input points in four isolated groups of eight points each. This allows each group of eight points to be used on a different phase of the AC supply. The input is reactive (resistor/capacitor input) with current-voltage characteristics which meet IEC standard (type 2). The input characteristics are compatible with a large range of available proximity switches. LED indicators which give the ON-OFF status of each point on the logic (PLC) side of the circuit are included at the top of the module. The module is mechanically keyed to ensure correct replacement with a similar type in the field. I/O references are user configurable without the use of jumpers or DIP switches on the module. Configuration is done using the configuration function of the MS-DOS or Windows programming software running on Windows 95 or Windows NT over Ethernet TCP/IP or through the SNP port. The Programming Software configuration function is installed on the programming device. The programming device can be an IBM) XT, AT,P S/2) or compatible Personal Computer. H N IBM and PS/2 are registered trademarks of International Business Machines Corporation. MS-DOS, Windows, Windows 95, and Windows NT are registered trademarks of Microsoft Corporation. GFK-0084J 120 Volt AC, 32-Point Input Module 2 Discrete Input Modules August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 39-2 Operation of the 120 VOLT AC Input Module SYSTEM INTERFACE VOLTAGE ATTENUATOR BACKPLANE a42140 FILTER LED FIELD CONNECTIONS MODULE NEUTRAL OPTO ISOLATOR ~ Input Characteristics The 120 Volt AC Input Module is compatible with a wide variety of input devices, such as: Pushbuttons, limit switches, selector switches Electronic proximity switches, both 2-wire and 3-wire The input circuitry is capacitive to give low heat dissipation and associated high reliability and long life. Input current characteristics provide 10mA typically in the ON state, and can sink up to 2.2mA of leakage current in the OFF state to the input device. This module is compatible with a wide range of both 2-wire and 3-wire proximity switches. To determine compatibility with a specific proximity switch, find the ON state characteristics of the switch in the illustration below. If that point falls to the left of the input load line, the ON state characteristics are compatible. As an example, the ON state requirements of a compatible proximity switch of 5mA at 20 volts drop is shown. In addition, the OFF-state current must be less than 2.2mA. ON-STATE VOLTAGE ACROSS PROXIMITY SWITCH 2 4 6 8 10 OPERATIONAL NON-OPERATIONAL I LOAD (mA) 120 VOLTS 100 VOLTS 45 25 0 a42232 3 120 Volt AC, 32-Point Input Module GFK-0084J Discrete Input Modules August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 39-3 Module Power The 120 Volt AC Input Module requires 0.35 amps from the 5-volt bus on the backplane. Module Mechanical Keying This module includes a mechanical key that prevents inadvertent substitution of one module type for another in a given slot. The key fits a uniquely shaped area on the board below the connector. The key is included with each module. When the module is first installed, the key latches onto the backplane center rail. When the module is extracted, the key remains in the center rail, configuring the slot to accept only identical module types. If it is necessary to change the module location in the rack after the key has been latched onto the center rail of the rack, the key can be removed by pushing it upward to unhook the latch while pulling it off the rail. It may then be reinserted onto the module and the module inserted into the rack in the desired location. Note that only the power supply can be placed in the leftmost rack position. Field Wiring The module is wired as shown in the illustration on the right of this page. Since each group of eight inputs is isolated from the others, a wire from the power source to the power input terminal for each group (terminal number 10, 20, 30, or 40) is required (power input terminals for each group are not connected inside the module). The detachable field wiring terminal board accepts wire sizes from #22 (0.36 mm2) through #14 (2.10 mm2). Two wires may be terminated on a given lug if both wires are the same size. There is room for a bundle of forty #14 wires to be routed out through the terminal board cavity. The wire bundle can be secured to the terminal board by passing a cable tie through a cleat located at the HINGED DOOR TERMINAL BOARD JACKSCREW JACKSCREW CORD TIE CLEAT STRAP CORD TIE CLEAT STRAP CORD TIE CORD TIE STRAP CLEAT Figure 1. I/O Module Features 1. Turn off power before removing or installing terminal boards. Open the hinged door on the module to access a jackscrew which holds the terminal board securely in place. The detachable field wiring terminal board can now be removed from the module by turning the jackscrew counter-clockwise until it is fully disengaged. 2. To remove the terminal board, grasp the top of the terminal board and swing it outward as shown in Figure 2. Caution Do not use the hinged door to remove the terminal board. The hinged door could be damaged if this is done. 3. The terminal board is designed to accept wire sizes from AWG #22 (0.36 mm) through AWG #14 (2.10 mm). It is important that when using AWG #14 (2.10 mm2) wire for wiring all points, that a maximum insulation diameter of .135 inch (3.43mm) not be exceeded. To ensure proper connection, two wires may be terminated on any one terminal only if both wires are the same size. 4. The terminal board is designed to accept a maximum of (40) AWG #14 (2.10 mm2)wires. If AWG #14 (2.10 mm2) wires are to be used, then wire markers should be placed at least 8 inches (203 mm) from termination end to provide sufficient space for the hinged door to close. 5 120 Volt AC, 32-Point Input Module GFK-0084J Discrete Input Modules August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F JACKSCREW a43747 WIRE BUNDLE CABLE TIE CLEAT DO NOT PULL ON DOOR Figure 2. Removal of I/O Terminal Board 5. After completing connections to all modules in a rack, the wire bundle must be secured. To ensure that the wire bundle is secured properly, it is recommended that a cable tie be wrapped around the wire bundle and tightly secured through the cable tie cleat located at the lower right corner of the terminal board. For extremely large wire bundles, additional cable ties should be used. 6. A door label insert is included with each module to indicate circuit wiring information and provide space to record user circuit wiring identification. A slot is provided on the hinged door to allow for insertion of this label. If the label is difficult to insert, crease the scored edge before insertion. The outside label has a color coded stripe to allow quick identification of the module voltage type (blue: low voltage; red: high voltage). 7. After field wiring is completed, the terminal board should be securely fastened to the rack by inserting the terminal board strap (attached to each module) into the small rectangular slots in the bottom card guide grill on the rack. This strap not only secures the terminal board to the rack, it also provides a way of identifying the wired terminal board with its correct mating rack slot location. 8. For adequate module ventilation, it is recommended that at least a 6 inch (152mm) clearance be allowed above and below the rack grill. Wire bundles should not obstruct the rack grill work. Removing an I/O Module The instructions below should be followed when removing an I/O module from its slot in a rack. Grasp the board firmly at the top and bottom of the board cover with your thumbs on the front of the cover and your fingers on the plastic clips on the back of the cover. Squeeze the rack clips on the back of the cover with your fingers to disengage the clip from the rack rail and pull the board firmly to remove it from the backplane connector. Slide the board along the card guide and remove it from the rack. GFK-0084J 120 Volt AC, 32-Point Input Module 6 Discrete Input

Need To Order A Specific Revision?

Give us a call at 1-800-360-6802 or 1-919-535-3180. We can help you with your Revision specific needs.


UPS Ground shipping is always FREE!


What is New Surplus?

These “New Surplus” units are a great cost saving alternative. This product is in the original manufacturer’s packaging with all sub-assemblies and documentation. Comes with a PDF Electric & Supply 3-year warranty.


UPS Ground shipping is always FREE!


What is Surplus New?

Surplus New - New unused and includes all sub-assemblies and documentation. Product may ship in manufacturer or PDF Electric & Supply packaging and includes a PDF Electric & Supply 3 Year Warranty.


UPS Ground shipping is always FREE!


What is Reconditioned?

Reconditioned products from PDF Electric & Supply are a cost-effective alternative to new and obsoleted PLC products. Every part is reconditioned down to the circuit board level. All parts are thoroughly inspected and hand-cleaned before being functionally tested in a fully configured system.


Our Reconditioned Products always come with a PDF Electric & Supply 2-Year Warranty.

UPS Ground shipping is always FREE!


110% PRICE MATCH GUARANTEE


We stand behind our prices with a 110% price match guarantee. If you buy a part from us and, within seven days of purchase, find that part advertised on an authorized distributor's website for less, simply contact us and give us a link to the lower advertised price and we'll refund you 110% of the difference between your purchase price and the advertised lower price. The part must be in-stock for immediate shipment and be in similar condition. All pricing must be displayed without signing in.

Repair Service


3-5 Days for most repairs. 24 hour repair upon request at no extra charge. If part is unrepairable, we will exchange with a working unit or return unrepaired.