IC697CPU789

GE Fanuc | 9070 | GE Fanuc 90-70 PLC

IC697CPU789 Image

IC697CPU789

Same Day - Free Shipping

  • Manufacturer: GE Fanuc
  • Description: GE Fanuc 90-70 GMR Redundancy CPU 386 2K Triplex Input/Output
  • Weight: 4 lbs :: ≈ 2 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC697CPU789 : -DA, -EA, -FA,

Product Manual Excerpt

Single slot CPU. Supports 512 Kbytes of battery-backed expansion memory in the same slot. (Up to approximately 200 Kbytes available for user s application program and data) Up to 12K discrete inputs and outputs (any mix, simplex mode only); 2048 voted discrete inputs, 2048 voted discrete outputs Up to 8K analog inputs (simplex mode only) and 8K analog outputs (simplex mode only); 1024 voted analog inputs 0.4 microseconds per boolean function 16 MHz, 80386DX microprocessor Supports IC660/IC661 I/O (and IC697 I/O in simplex mode only) Programmed by MS-DOS , or Windows software products running on Windows 95 or Windows NT over Ethernet TCP/IP or through the SNP port Configurable data and program memory Battery-backed calendar clock Three position operation mode switch Password controlled access Remote programmer keyswitch memory protection Four status LEDs Software configuration (No DIP switches or jumpers) Reference information inside front door. Functions The CPU 789 is a single slot programmable controller CPU which is programmed and configured by MS-DOS or Windows based programming software for use in Emergency Shut-Down (ESD), fire and gas, and other critical control applications. It communicates with I/O and smart option modules over the rack mounted backplane (IC697CHS750, 782, 783, 790, 791) by way of the VME C.1 Standard format. The CPU 789 must be used in conjunction with a set of C program blocks which provide Triple Modular Redundancy (TMR) operating and autotest routines. It will not operate unless these program blocks are included in the loaded application program. For detailed information on TMR systems, see Reference 4, the IC660/661 Modular Redundancy Flexible Triple Modular Redundant (TMR) System User s Manual. PROGRAMMER a45235 OK RUN ENABLED MEM PROTECT CENTRAL PROCESSOR MODULE IC697CPU789 LABEL 44A726758-134R01 SERIAL PORT USE THIS MODULE IN SLOT 1 ONLY CPU 789 OFF ON TOP REMOTE PROGRAMMER MODULE OK RUN OUTPUTS ENABLED ON = OK, ENABLED, FRONT RUN WITH OUTPUTS ENABLED RUN WITH OUTPUTS DISABLED STOP KEY POSITION MODULE FUNCTION 16MHz 32 BIT CENTRAL PROCESSING UNIT BATTERY CONNECTORS INSTALL NEW BATTERY BEFORE UNPLUGGING OLD BATTERY. USE IC697ACC701 MEMORY PROTECT MEMORY REMOTE ONLY RS-485 COMPATIBLE PROTECT PROTECTED MS-DOS, Windows, Windows 95, and Windows NT are registered trademarks of Microsoft Corporation. 16 MHz, 32-Bit Expandable Central Processing Unit for IC66* Triple Modular Redundancy Systems GFK-0807D 2 PLC CPUs August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 26-2 Supported option modules include IC697 LAN Interface modules, Programmable Coprocessor, Alphanumeric Display Coprocessor, Bus Controller for IC660/IC661 I/O products, Communications modules, I/O Link Interface, and all of the IC697 family of discrete and analog I/O modules. Triple Input Sensors Triple Genius Busses Triple PLCs Load a47059 Figure 1. Typical GMR System Configuration User Memory Program and data memory for the CPU 789 is available by attaching an expansion memory board with 512 Kbytes battery-backed CMOS RAM. Up to approximately 200 Kbytes of this memory is available for the user application program and data. Operation, Protection, and Module Status Operation of this module may be controlled by the three-position RUN/STOP switch or remotely by an attached programmer and IC641 software. Program and configuration data can be locked through software passwords or manually by the memory protect keyswitch. When the key is in the protected position, program and configuration data can only be changed by a programmer connected parallel only (that is, via the Bus Transmitter module). The status of a CPU is indicated by the four green LEDs on the front of the module. Installation It is the responsibility of the OEM, system integrator, or end user to properly install the PLC equipment for safe and reliable operation. Product manuals provide detailed information about installation, startup, and proper use of the PLC equipment. The installation manual, shipped with your PLC programming software, describes how to properly install the equipment. If the PLC installation must comply with supported standards, such as FCC or CE Directives, please refer to the Installation Requirements for Conformance to Standards, shipped with the PLC programming software, for additional guidelines. Installation should not be attempted without referring to the applicable programmable controller hardware installation manual. Align the expansion memory and CPU connectors. Align the captive screws on the memory board with the standoffs already installed on the CPU. Push the memory board onto the CPU connector ensuring the mating screws remain aligned with their respective standoff. Screw each memory board screw into the standoffs with a #1 Phillips screwdriver, firmly tighten each. Connect the battery to either of the battery connectors on the module. Put toggle switch in the STOP position. Put keyswitch in Memory Protection OFF position. Make sure rack power is off. Install in slot 1 of rack 0. Turn on power. 3 16 MHz, 32-Bit Expandable Central Processing Unit for IC66* Triple Modular Redundancy Systems GFK-0807D PLC CPUs August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 26-3 The module should power up and blink the top LED. When the diagnostics have completed successfully, the top LED stays on and the second and third LEDs are off. The fourth LED is off if the keyswitch is in the OFF position. The CPU is now ready to be programmed (if connected parallel, the CPU can be programmed regardless of key position). After the program has been verified the toggle switch may be moved to the appropriate operation mode position. The LEDs indicate the position of the toggle switch, memory protection status, and the state of the program. Expansion Memory The CPU 789 must have a CMOS RAM expansion memory board. The CMOS expansion memory board provides CMOS RAM memory of 512 Kbytes. Up to approximately 200 Kbytes of this memory is available for the user application program and data. The battery which supports this memory is located on the main CPU board housing. Installation of a CMOS expansion memory board on the CPU will require initialization of the CPU with the programmer (See Reference 2). Programmer Connection, Parallel For a parallel interface (MS-DOS programmer only) the programmer is connected to the top port on the Bus Transmitter Module (IC697BEM713). Consult Reference 1 for a description of programming functions. MEMORY PROTECT a45236 OPEN REPLACEMENT BATTERY CONNECTOR EXPANSION MEMORY BOARD IC697MEM735 CPU 789 CURRENTLY INSTALLED BATTERY CONNECTOR MEMORY PROTECT KEY MODULE IC697CPU789 LABEL 44A726758 134R01 SERIAL PORT USE THIS MODULE IN SLOT 1 ONLY CPU 789 OFF ON TOP REMOTE PROGRAMMER MODULE OK RUN OUTPUTS ENABLED ON = OK, ENABLED, PROTECTED FRONT RUN WITH OUTPUTS ENABLED RUN WITH OUTPUTS DISABLED STOP KEY POSITION MODULE FUNCTION 16MHz 32 BIT CENTRAL PROCESSING UNIT BATTERY CONNECTORS INSTALL NEW BATTERY BEFORE UNPLUGGING OLD BATTERY. USE IC697ACC701 MEMORY PROTECT REMOTE PROGRAMMER ONLY RS-485 COMPATIBLE Figure 2. CPU 789 - Location of Major Features 16 MHz, 32-Bit Expandable Central Processing Unit for IC66* Triple Modular Redundancy Systems GFK-0807D 4 PLC CPUs August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 26-4 CPU CPU CPU RS 232/422 Converter Multidrop Cable PLC A Multidrop cable is catalog number IC690CBL714 (1 cable). Two cables are needed for 3 CPUs. PLC B PLC C a47100 Figure 3. System Configuration, Serial Connection to Programmer Serial Port The 15-pin D-connector provides the connection to an RS-485 compatible serial port on the CPU as shown in Figure 3. This port provides a serial connection to a Work Station Interface board installed in the programming computer. The serial connection can also be made from the serial port on the CPU to the serial port on the programming computer, or other serial device, through the RS-422/RS-485 to RS-232 Converter (IC690ACC900) or RS-232 to RS-422 Miniconverter (IC690ACC901). This connection can be made with available cables or you may build cables to fit the needs of your particular application. For more information on serial communications, see reference 3. For more detailed information on configuration of TMR systems and communications between PLCs in the system, refer to the Modular Redundancy Flexible Triple Modular Redundant (TMR) System User s Manual. Programmer Connection, Ethernet TCP/IP Connecting your programmer via an Ethernet TCP/IP network requires installation of an Ethernet Interface module in the PLC. This can be either the Ethernet Controller, IC697CMM741, or Ethernet Interface (Type 2), IC697CMM742. Before connecting your programmer and PLC to the Ethernet TCP/IP network you must set the IP address in the Ethernet Interface. After setting the IP address, connect the PLC and the programmer running Windows software to the Ethernet Interface. For more detailed information on Ethernet TCP/IP, refer to the TCP/IP Ethernet Communications (Type 2) User s Manual, and the Windows

Need To Order A Specific Revision?

Give us a call at 1-800-360-6802 or 1-919-535-3180. We can help you with your Revision specific needs.


UPS Ground shipping is always FREE!


What is New Surplus?

These “New Surplus” units are a great cost saving alternative. This product is in the original manufacturer’s packaging with all sub-assemblies and documentation. Comes with a PDF Electric & Supply 3-year warranty.


UPS Ground shipping is always FREE!


What is Surplus New?

Surplus New - New unused and includes all sub-assemblies and documentation. Product may ship in manufacturer or PDF Electric & Supply packaging and includes a PDF Electric & Supply 3 Year Warranty.


UPS Ground shipping is always FREE!


What is Reconditioned?

Reconditioned products from PDF Electric & Supply are a cost-effective alternative to new and obsoleted PLC products. Every part is reconditioned down to the circuit board level. All parts are thoroughly inspected and hand-cleaned before being functionally tested in a fully configured system.


Our Reconditioned Products always come with a PDF Electric & Supply 2-Year Warranty.

UPS Ground shipping is always FREE!


110% PRICE MATCH GUARANTEE


We stand behind our prices with a 110% price match guarantee. If you buy a part from us and, within seven days of purchase, find that part advertised on an authorized distributor's website for less, simply contact us and give us a link to the lower advertised price and we'll refund you 110% of the difference between your purchase price and the advertised lower price. The part must be in-stock for immediate shipment and be in similar condition. All pricing must be displayed without signing in.

Repair Service


3-5 Days for most repairs. 24 hour repair upon request at no extra charge. If part is unrepairable, we will exchange with a working unit or return unrepaired.