IC697CPM915

GE Fanuc | 9070 | GE Fanuc 90-70 PLC

IC697CPM915 Image

IC697CPM915

Same Day - Free Shipping

  • Manufacturer: GE Fanuc
  • Description: GE Fanuc 90-70 CPU 32 MHz 12K Discrete Input/Output 1024K RAM
  • Weight: 4 lbs :: ≈ 2 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC697CPM915 : -AA, -AB, -BB, -BC, -CC, -CE, -CF,

Product Manual Excerpt

Features Single slot CPU Provides 1 Mbyte of battery-backed memory in the same slot Supports floating point calculations 12K inputs and outputs (any mix) Up to 8K analog I/O 0.4 microseconds per boolean function 32 MHz, 80486DX microprocessor Supports IC660/IC661 and IC697 I/O) Programmed by MS-DOS or Windows software products running on Windows 95 or Windows NT over Ethernet TCP/IP or through the SNP port. Configurable data and program memory Battery-backed calendar clock Three position operation mode switch Password controlled access Remote programmer keyswitch memory protection Four status LEDs Software configuration (No DIP switches or jumpers) Reference information inside front door In-system upgradable firmware Functions The CPM 915 Central Processing Unit (CPU) is a single slot programmable controller CPU which allows floating point calculations. The CPM915 is programmed and configured by MS-DOS or WIndows based programming software to perform real time control of machines, processes and material handling systems. It communicates with I/O and smart option modules over the rack mounted backplane (IC697CHS750, 782, 783, 790, 791) by way of the VME C.1 Standard format. Supported option modules include all IC697 LAN interface modules, several Coprocessor modules, Bus Controller for IC660/IC661 I/O, Communications modules, and all of the IC697 family of discrete and analog I/O modules. PROGRAMMER IC697CPM915 LABEL 44A726758-146R01 SERIAL PORT USE THIS MODULE CPM 915 OFF ON TOP REMOTE PROGRAMMER MROUNDULE OK OUTPUTS ENABLED ON = OK, ENABLED, FRONT RUN WITH OUTPUTS ENABLED RUN WITH OUTPUTS DISABLED STOP KEY POSITION MODULE FUNCTION 32 MHz 32 BIT CENTRAL PROCESSING UNIT WITH BATTERY CONNECTORS INSTALL NEW MEMORY PROTECT MEMORY REMOTE ONLY RS-485 COMPATIBLE PROTECT PROTECTED FLOATING POINT MATH COPROCESSOR, IN-SYSTEM UPGRADABLE FIRMWARE BATTERY BEFORE UNPLUGGING OLD BATTERY. USE IC697ACC701 IN SLOT 1 ONLY. MS-DOS, Windows, Windows 95, and Windows NT are registered trademarks of Microsoft Corporation. GFK-1119B 32 MHz 32-Bit Floating Point Central Processing Unit, 1 Mbyte Memory 2 PLC CPUs August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F RACK 7 BRM GBC BRM ONE METER ONE METER IC66* I/O BUS (7500 FEET (2285 METERS) MAXIMUM) PS I/O TERMINATOR (LAST RACK) TOTAL LENGTH OF ALL INTERCONNECTING CABLES FROM BTM TO LAST BRM IS 50 FEET (15 METERS) MAXIMUM. ALL RACKS MUST BE AT SAME GROUND POTENTIAL (8 RACKS MAXIMUM). NOTE LEGEND CPU - SELECTED CPU MODEL BRM - BUS RECEIVER MODULE, BEM711 BTM - BUS TRANSMITTER MODULE, BEM713 GBC/NBC - BUS CONTROLLER, BEM731/734 PCM - PROGRAMMABLE COPROCESSOR MODULE, PCM711 PS - POWER SUPPLY, PWR710/711/724/748 PARALLEL or NBC or NB C Figure 1. Typical Programmable Controller System Configuration User Memory Program and data memory for the CPM 915 is provided by a memory board with 1M byte of batterybacked CMOS RAM. This memory board is an integral part of the CPM 915 module and does not need to be ordered separately. Flash Memory This module uses flash memory for storage of the operating system firmware (Note that this module does not support storage of user program in the flash memory). This allows updates of the firmware without disassembling the module or replacing EPROMs. The operating system firmware is updated by connecting a PC compatible computer to the serial port of the module and running the Loader software included with the firmware floppy disk. Operation, Protection, and Module Status Operation of this module can be controlled by the three-position RUN/STOP switch or remotely by an attached programmer and programming software. Program and configuration data can be locked through software passwords or manually by the memory protect keyswitch. When the key is in the protected position, program and configuration data can only be changed by a programmer connected parallel only (to the Bus Transmitter module). The status of a CPU is indicated by the four green LEDs on the front of the module. Installation It is the responsibility of the OEM, system integrator, or end user to properly install the PLC equipment for safe and reliable operation. Product manuals provide detailed information about installation, startup, and proper use of the PLC equipment. The installation manual, shipped with your PLC programming software, describes how to properly install the equipment. If the PLC installation must comply with supported standards, such as FCC or CE Directives, please refer to the Installation Requirements for Conformance to Standards, shipped with the PLC programming software, for additional guidelines. Installation should not be attempted without referring to the applicable programmable controller hardware installation manual. Connect the battery to either of the battery connectors on the module (see Figure 2). Put the toggle switch in the STOP position. Put the keyswitch in Memory Protection OFF position. Make sure that rack power is off. Install the CPM 915 module in slot 1 of rack 0 (see Figure 1). Turn on power. The module should power up and the top LED should blink. When the diagnostics have completed successfully, the top LED stays on and the second and third LEDs are off. The fourth LED is off if the keyswitch is in the OFF position. The CPU is now ready to be programmed (if connected parallel, the CPU can be programmed regardless of key position). 3 32 MHz 32-Bit Floating Point Central Processing Unit, 1 Mbyte Memory GFK-1119B PLC CPUs August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 17-3 After the program has been verified the toggle switch may be moved to the appropriate operation mode position. The LEDs indicate the position of the toggle switch, memory protection status, and the state of the program. MEMORY PROTECT a47066 OPEN REPLACEMENT BATTERY CONNECTOR 1 MBYTE MEMORY BOARD CPM 915 CURRENTLY INSTALLED BATTERY CONNECTOR MEMORY PROTECT KEY SWITCH IC697CPM915 LABEL 44A726758 146R01 SERIAL PORT USE THIS MODULE IN SLOT 1 ONLY CPM 915 OFF ON TOP REMOTE PROGRAMMER MODULE OK RUN OUTPUTS ENABLED ON = OK, ENABLED, PROTECTED FRONT RUN WITH OUTPUTS ENABLED RUN WITH OUTPUTS DISABLED STOP KEY POSITION MODULE FUNCTION BATTERY CONNECTORS INSTALL NEW BATTERY BEFORE UNPLUGGING OLD BATTERY. USE IC697ACC701 MEMORY PROTECT REMOTE PROGRAMMER ONLY RS-485 COMPATIBLE 32 MHz 32 BIT CENTRAL PROCESSING UNIT WITH FLOATING POINT MATH COPROCESSOR, IN-SYSTEM UPGRADABLE FIRMWARE Figure 2. CPM 915 - Location of Major Features Programmer Connection, Parallel For a parallel interface (MS-DOS based programmer only) the programmer is connected to the top port on the Bus Transmitter Module (IC697BEM713) as shown in Figure 1. Consult Reference 1 for a description of programming functions. Serial Port The 15-pin D-connector provides the connection to an RS-485 compatible serial port on the CPU as shown in Figure 3. This port provides a serial connection to a Work Station Interface board installed in the programming computer. The serial connection can also be made from the serial port on the CPU to the serial port on the programming computer, or other serial device, through the RS-422/RS-485 to RS-232 Converter (IC690ACC900) or RS-232 to RS-422 Miniconverter (IC690ACC901). This connection can be made with available cables or you may build cables to fit the needs of your particular application. See reference 3 for more information on serial communications. PS CPU BTM BRM IC66* I/O BUS (7500 FEET (2285 METERS) MAXIMUM) RACK 7 ONE METER TOTAL LENGTH OF ALL INTERCONNECTING CABLES FROM BTM TO LAST BRM IS 50 FEET (15 METERS) MAXIMUM. ALL RACKS MUST BE AT SAME GROUND POTENTIAL (8 RACKS MAXIMUM). NOTE SERIAL TERMINATOR PLUG (IC697ACC702) PCM or NBC GB C Figure 3. System Configuration, Serial Connection to Programmer GFK-1119B 32 MHz 32-Bit Floating Point Central Processing Unit, 1 Mbyte Memory 4 PLC CPUs August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 17-4 Programmer Connection, Ethernet TCP/IP Connecting your programmer via an Ethernet TCP/IP network requires installation of an Ethernet Interface module in the PLC. This can be either the Ethernet Controller, IC697CMM741, or Ethernet Interface (Type 2), IC697CMM742. Before connecting your programmer and PLC to the Ethernet TCP/IP network you must set the IP address in the Ethernet Interface. After setting the IP address, connect the PLC and the programmer running Windows software to the Ethernet Interface. For more detailed information on Ethernet TCP/IP, refer to the TCP/IP Ethernet Communications (Type 2) User s Manual, and the Windows programming manual, GFK-1295. Configuration The IC697 CPU and I/O system is configured with MS-DOS or Windows based programming software. There are no DIP switches or jumpers used to configure the system. The CPU verifies the actual module and rack configuration at power-up and periodically during operation. The actual configuration must be the same as the programmed configuration. Deviations are reported to the CPU alarm processor function for configured fault response. Consult Reference 1 for a description of configuration functions. Batteries A lithium battery (IC697ACC701) is installed as shown in Figure 2. This battery maintains program and data memory when power is removed and operates the calendar clock. Be sure to install the new battery before removing the old battery. Specific indication of a low battery state is detailed in Reference 2. Removing a Module The instructions below should be followed when removing a module from its slot in a rack. Grasp the board firmly at the top and bottom of the board cover with your thumbs on the front of the cover and your fingers on the plastic clips on the back of the cover. Squeeze the rack clips on the back of the cover with your fingers to disengage the clip from the rack rail and pull the board firmly to remove it from the backplane connector. Slide the board along the card guide and remove it from the rack. Table 1. References Reference Title 1 Programming Software User s Manual 2 Programmable Controller Reference Manual 3 Programmable Controller Installation Manual 5 32 MHz 32-Bit Floating Point Central Processing Unit, 1 Mbyte Memory GFK-1119B PLC CPUs August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 17-5 Table 2. Specifications for IC697CPM915 Battery Shelf life 10 years at 20 C (68 F) Memory retention 6 months nominal without applied power. Current required from 5V bus 2.8 Amps nominal Time of Day Clock accuracy \" 3.5 seconds per day maximum Elapsed Time Clock (internal timing) accuracy \" .01% maximum Serial Port RS422/485 compatible Programmer Serial Attachment VME System designed to support the VME standard C.1 Refer to GFK-0867B, or later for product standards and general specifications. Table 3. Ordering Information Description Catalog Number Central Processing Unit 32 MHz, 32-Bit, Floating Point, 1 Mbyte Memory IC697CPM915 Lithium Battery

Need To Order A Specific Revision?

Give us a call at 1-800-360-6802 or 1-919-535-3180. We can help you with your Revision specific needs.


UPS Ground shipping is always FREE!


What is New Surplus?

These “New Surplus” units are a great cost saving alternative. This product is in the original manufacturer’s packaging with all sub-assemblies and documentation. Comes with a PDF Electric & Supply 3-year warranty.


UPS Ground shipping is always FREE!


What is Surplus New?

Surplus New - New unused and includes all sub-assemblies and documentation. Product may ship in manufacturer or PDF Electric & Supply packaging and includes a PDF Electric & Supply 3 Year Warranty.


UPS Ground shipping is always FREE!


What is Reconditioned?

Reconditioned products from PDF Electric & Supply are a cost-effective alternative to new and obsoleted PLC products. Every part is reconditioned down to the circuit board level. All parts are thoroughly inspected and hand-cleaned before being functionally tested in a fully configured system.


Our Reconditioned Products always come with a PDF Electric & Supply 2-Year Warranty.

UPS Ground shipping is always FREE!


110% PRICE MATCH GUARANTEE


We stand behind our prices with a 110% price match guarantee. If you buy a part from us and, within seven days of purchase, find that part advertised on an authorized distributor's website for less, simply contact us and give us a link to the lower advertised price and we'll refund you 110% of the difference between your purchase price and the advertised lower price. The part must be in-stock for immediate shipment and be in similar condition. All pricing must be displayed without signing in.

Repair Service


3-5 Days for most repairs. 24 hour repair upon request at no extra charge. If part is unrepairable, we will exchange with a working unit or return unrepaired.