IC697CHS782

GE Fanuc | 9070 | GE Fanuc 90-70 PLC

IC697CHS782 Image

IC697CHS782

Same Day - Free Shipping

  • Manufacturer: GE Fanuc
  • Description: Double slot Integrators Rack 17 Slots Rear Mount
  • Weight: 4 lbs :: ≈ 2 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC697CHS782 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z,

Product Manual Excerpt

Features Accepts 3rd Party VME modules which require 0.8 spacing. Accepts all IC697 PLC module types. Rear mount rack mounts in a 10 (254 mm) deep enclosure. Front mount rack mounts in a standard 19 (483 mm) rack. Accepts plug-in AC/DC and DC IC697 power supplies, or can use external supply (Power Supply Adaptor module required). Provision for two rack operation from single power supply. Provision for power supply for high-current configurations. Optional accessory kit available for adding J2 backplane or making ribbon cable connections to J2 backplanes. Optional fan assembly (for high-power modules). Functions The VME Integrator Rack for the IC697 Programmable Logic Controller can be used for 3rd party VME modules and all IC697 CPU and I/O configurations, except redundancy applications. This rack has a 17-slot backplane and is designed to provide easy integration of 3rd party VME modules into an IC697 PLC system. Integration of 3rd Party VME modules must be in accordance with guidelines which are described in the User s Guide to Integration of 3rd Party VME Modules. Backplane connectors are spaced on 0.8 inch centers to accommodate 3rd party VME modules. IC697 modules each use two of these slots. Standard IC697 racks have slots spaced on 1.6 inch centers for IC697 modules. VME modules that require 0.8 inch spacing for installation in a rack may not fit in the standard IC697 racks(I C697CHS750/790/791). a44958 0V +5V +12V -12V 1 2 3 4 5 6 7 8 9 GFK-0684G VME Integrator Racks, 17 Slot Front and Rear Mount 2 PLC Racks November 1999 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 5-2 Each rack configuration will accept one power supply in the leftmost module position, and either: 1. seventeen (17) 3rd Party VME modules (with no IC697 modules installed), 2. nine (9) IC697 modules, or 3. a combination of IC697 and 3rd Party VME modules. The power supply capacity may limit the number of modules in a rack. No more than three VME modules can be used in a rack with IC697 modules. The flexibility of these racks to allow both 3rd party VME and IC697 modules is accomplished through the use of jumpers on the backplane to configure slots. The VME Integrator rack is factory configured to accept standard IC697 modules. Integration of 3rd party VME modules is done by moving these jumpers to different positions. The exact jumper configuration depends on the requirements of each 3rd Party VME module. Two racks can be interconnected to share a single power supply for applications having extended I/O requirements. A Power Supply Extension Cable kit (IC697CBL700) is available for such applications. There are also four power cube screw connections (+ 5V, +12V, -12V, 0V) on the backplane. These connections are not intended for direct connection to a 3rd Party power supply. Each rack provides slot sensing for rack-type I/O modules. No jumpers or DIP switches on the I/O modules are required for addressing of these modules. Overall rack dimensions are 11.15 H x 19 W x 7.25 D (283mm x 483mm x 184mm). Slots are 0.8 wide except the power supply slot which is 2.4 wide. The following figures show mounting dimensions for the rear mount (Figure 1) and the front mount (Figure 2) racks. ALLOWANCE FOR COOLING GROUND STUD 1.50 (38) 3.00 (76) (IF REQUIRED FOR ADDITIONAL COOLING, RACK FAN ASSEMBLY (IC697ACC721 OR IC697ACC724) IS AVAILABLE. .25 DIA. (TYPICAL) 11.15 (283) DIMENSIONS IN INCHES, MILLIMETERS ARE IN PARENTHESIS 19.00 (483) 18.11 (460) 17.04 (433) * 6.00 (152.4) *** a44989 * .45 (11) 6.00 (152.4) ** SIDE VIEW 6.00 (152.4) *** FRONT VIEW * ALLOW SUFFICIENT HORIZONTAL CLEARANCE FOR ACCESS TO GROUND STUDS AT EACH END OF THE RACK. IF THE EXTENSION CABLE IS USED, ALLOW APPROXIMATELY 6 INCH HORIZONTAL CLEARANCE ON THE LEFT SIDE OF THE RACK FOR ACCESS TO THE CONNECTOR. * * *** IC697 MODULES EXTEND 1.7 IN. (43MM) BEYOND FRONT OF RACK, VME MODULES MAY FIT FLUSH WITH FRONT OF RACK. 7.25 (184) 9.14 (232) GROUND STUD CONNECTOR FOR POWER SUPPLY 1.00 (25.4) WITH OPTIONAL VME J2 BACKPLANE KIT SPACER (QTY.4) 6.75 (172) 2.24 (57) .34 (8.64) .75 (19) Figure 1. VME Integrator Rack Dimensions for Rack (Rear) Mount Rack Mounting The rack must be mounted in the orientation shown above. Sufficient space must be left around the rack as shown in Figure 1 to allow air flow for module cooling. A Rack Fan Assembly (IC697ACC721 or IC697ACC724) is available for installations requiring forced air cooling (see data sheet GFK-0637 for detailed information on the fan assembly). The mounting requirements (either front or rear mount) must be determined according to the application and the proper rack ordered. Mounting flanges are an integral part of rack side panels and are installed at the factory. 3 VME Integrator Racks, 17 Slot Front and Rear Mount GFK-0684G PLC Racks November 1999 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 5-3 These racks accommodate two module types. First, rack-type IC697 high-density I/O modules, which use a detachable field wiring terminal board. Each I/O module will accept up to forty AWG #14 (2.10 mm2 ) wires. The wire bundle is routed out the bottom of the terminal board cavity where a cleat is provided for a tie wrap to secure the bundle to the terminal board housing. The second type of modules are VME modules which may have varying methods of connecting to field devices. .265 x .437 GROUND STUD (IF REQUIRED FOR ADDITIONAL COOLING, RACK FAN ASSEMBLY (IC697ACC721 OR IC697ACC724) IS AVAILABLE. 11.15 (283) DIMENSIONS IN INCHES, MILLIMETERS ARE IN PARENTHESIS 19.00 (483) 18.34 (466) 17.04 (433) * 6.00 (152.4) * * * a45219 * .45 (11) 6.00 (152.4) * * SIDE VIEW 6.00 (152.4) * * * FRONT VIEW * ALLOW SUFFICIENT HORIZONTAL CLEARANCE FOR ACCESS TO GROUND STUDS AT EACH END OF THE RACK. IF THE EXTENSION CABLE IS USED, ALLOW APPROXIMATELY 6 INCH HORIZONTAL CLEARANCE ON THE LEFT SIDE OF THE RACK FOR ACCESS TO THE CONNECTOR. * * * * * ALLOWANCE FOR COOLING IC697 MODULES EXTEND 1.7 IN. (43MM) BEYOND FRONT OF RACK, VME MODULES MAY FIT FLUSH WITH FRONT OF RACK. 7.25 (184) 9.14 (232) GROUND STUD CONNECTOR FOR POWER SUPPLY 1.00 (25.4) WITH OPTIONAL VME J2 BACKPLANE KIT SPACER (QTY.4) (191) (TYPICAL) Figure 2. VME Integrator Rack Dimensions for Panel (Front) Mount Configuring the VME Integrator Rack A series of jumper positions are located on the backplane near each slot. These jumpers provide for flexibility in the types of modules to be installed, either VME modules in single slots (0.8 inch spacing between centers) or IC697 modules, which require two slots (1.6 inch spacing between centers). IC697 module slots are indicated by a number and an arrow: also these slots are marked 1A through 9A. Table 1 on page 5 shows the relationship of the slot numbers to the jumper numbers. The functions and signals which are configurable by these jumpers are: select a rack ID for multiple rack systems (IC697 feature). configure SYSFAIL signal to be enabled or disabled (per slot). configure LWORD signal in slot 1 to be inactive. configure IRQ1/ - IRQ4/ signals for VME slots 12PL to 19PL. configure Bus Grant signals for VME slots 12PL to 19PL. GFK-0684G VME Integrator Racks, 17 Slot Front and Rear Mount

Need To Order A Specific Revision?

Give us a call at 1-800-360-6802 or 1-919-535-3180. We can help you with your Revision specific needs.


UPS Ground shipping is always FREE!


What is New Surplus?

These “New Surplus” units are a great cost saving alternative. This product is in the original manufacturer’s packaging with all sub-assemblies and documentation. Comes with a PDF Electric & Supply 3-year warranty.


UPS Ground shipping is always FREE!


What is Surplus New?

Surplus New - New unused and includes all sub-assemblies and documentation. Product may ship in manufacturer or PDF Electric & Supply packaging and includes a PDF Electric & Supply 3 Year Warranty.


UPS Ground shipping is always FREE!


What is Reconditioned?

Reconditioned products from PDF Electric & Supply are a cost-effective alternative to new and obsoleted PLC products. Every part is reconditioned down to the circuit board level. All parts are thoroughly inspected and hand-cleaned before being functionally tested in a fully configured system.


Our Reconditioned Products always come with a PDF Electric & Supply 2-Year Warranty.

UPS Ground shipping is always FREE!


110% PRICE MATCH GUARANTEE


We stand behind our prices with a 110% price match guarantee. If you buy a part from us and, within seven days of purchase, find that part advertised on an authorized distributor's website for less, simply contact us and give us a link to the lower advertised price and we'll refund you 110% of the difference between your purchase price and the advertised lower price. The part must be in-stock for immediate shipment and be in similar condition. All pricing must be displayed without signing in.

Repair Service


3-5 Days for most repairs. 24 hour repair upon request at no extra charge. If part is unrepairable, we will exchange with a working unit or return unrepaired.