IC697ALG320

GE Fanuc | 9070 | GE Fanuc 90-70 PLC

IC697ALG320 Image

IC697ALG320

Same Day - Free Shipping

  • Manufacturer: GE Fanuc
  • Description: Analog Output, Voltage/Current, 4 Channels
  • Weight: 4 lbs :: ≈ 2 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC697ALG320 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z,

Product Manual Excerpt

High Level Analog Output System - Voltage/Current Module IC697ALG320 Analog Modules GFK-0388G August 1997 1 58 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 58-1 High Level Analog Output System - Voltage/Current Module (IC697ALG320) datasheet GFK-0388G Features High Level Analog voltage and current outputs on one module Output module has four outputs individually configurable for voltage or current Provides unipolar or bipolar Analog voltage outputs up to 10 volts full scale Provides 0 to 22.5 milliamp current loop signals Individual user scaling on each output channel Fast update rate No jumpers or DIP switches for user to configure Calibrated at factory with factory calibration data stored in non-volatile EEPROM memory Easy configuration using the configuration function of the MS-DOS or Windows programming software running on Windows 95 or Windows NT over Ethernet TCP/IP or through the SNP port. The Programming Software configuration function is installed on the programming device. The programming device can be an IBM XT, AT, PS/2 or compatible Personal Computer. Functions The high level Analog Output system for the Programmable Logic Controller (PLC) accepts digital data from the CPU or other controllers accessing the PLC backplane. This output data is converted by a Digital to Analog (D/A) converter to analog outputs of up to 10 volts full scale, or 0 to 22.5 milliamp current loop signals. The basic converter is 16 bits resolution (1 part in 65536) with 14-bit monotonicity. Outputs are isolated from the backplane and are protected against transient and steady-state overvoltage conditions. Analog outputs use %AQ references in the PLC. A maximum of 8K words of %AQ memory is available in the PLC. Each output channel uses one word (16 bits) of %AQ memory. 20 USER 35 OUTPUT ANALOG (V&I) Figure 1. High Level Analog Output Module IBM and PS/2 are registered trademarks of International Business Machines Corporation. MS-DOS, Windows, Windows 95, and Windows NT are registered trademarks of Microsoft Corporation. GFK-0388G High Level Analog Output System - Voltage/Current Module 2 Analog Modules August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 58-2 System Operation A block diagram of the IC697ALG320 High Level Analog Output module and an example of user field wiring connections to the module are shown below. GND VOUT JUMPER FOR OUTPUT OUT RET GND VC 4 20MA D LOAD A VOLTAGE OUTPUT OPTO ISOLATION PLC BACKPLANE CH 1 VOUT 10V VLOAD GND VOLTAGE OUTPUT CH 2 VRET OUT RET GND GND VCM USER POWER SUPPLY USER GROUND 10K MODULE GROUND .001 PWR PWR + REF Figure 2. Block Diagram and User Wiring Information for IC697ALG320 Connections for both voltage and current loads are shown in the above illustration. Note the following regarding the illustration: 1. Each output may be configured for either voltage or current - not both. 2. If used as a current output you must jumper VOUT to IREF. 3. Power for the voltage output is derived from the PLC backplane. Power for the 4 to 20 mA current output must be supplied by the user. A single connection (PSPOS and PSNEG) serves all four channels. 3 High Level Analog Output System - Voltage/Current Module GFK-0388G Analog Modules August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 58-3 Channel-to-Channel Compliance While it is expected that output loads will be floating or tied to the same potential (normally ground), the module is designed to allow up to 0.5 VDC compliance voltage (labeled VC in the previous illustration) difference between outputs and still operate within specifications. This prevents ground loop currents or errors from occurring due to small differences in ground potential at different locations. Note that in addition to this offset, outputs will operate properly in the presence of a large amount of high frequency noise (refer to specifications). As shown in the previous illustration. the output circuitry is isolated from the PLC backplane. This allows the module to operate within specifications with a common mode voltage of up to 60V from ground (shown as VCM in the illustration). It must be observed, however that the entire output section of the module (all four channels) operates at a single offset voltage from ground potential. Common mode voltage between outputs must be within the specifications stated in the previous paragraph. User Power for Current Loops This module will accommodate a wide range of load impedance; up to 800 ohms. The range of allowable power supply voltage for a given load impedance is shown in Figure 3. For example, a 24V 20% supply (19.2 to 28.8 volts) will provide sufficient power with loads from 200 to 550 ohms. MIN MAX SUPPLY) Figure 3. User Power vs. Load Impedance User Wiring Connections Figure 4 shows the wiring assignments for the screw terminals on the terminal board on the Analog Output module. In addition to the information in this data sheet, circuit wiring diagrams are printed on the inside surface of the label inserted in the module s hinged door. Figure 4. Field Wiring Connections to Module s I/O Terminal Board GFK-0388G High Level Analog Output System - Voltage/Current Module 4 Analog Modules August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 58-4 Connections to User Devices Connections to the Analog Output module from user devices are made to screw terminals on a removable 40-terminal connector block mounted on the front of the module. All field connections to the outputs should be wired to the I/O terminal board using a good grade of twisted, shielded instrumentation cable. Separate connections are provided on the terminal board for both current outputs and voltage outputs for each channel. Actual terminals used are determined by the configuration that has been selected for each individual channel. Ground connections for each channel, labeled GND, on the terminal board are provided for connecting shields. This ground connection is made directly to the rack, resulting in superior rejection of noise caused by any shield drain currents. Actual selection of ground location may be influenced by system power and ground considerations. However, best operation will be obtained when system ground is physically close to the rack containing the analog circuits. Normally, the shield is grounded at only one end (see Figure 5). For additional system grounding information refer to the discussion on system grounding in chapter 3 of the Programmable Controller Installation Manual. The module provides electrical isolation of externally generated noise between the output field wiring and the backplane through use of optical isolation. OUT REF OUT RET RET NC USER DEVICE a43974 GND CURRENT: V GND VOUT V RET USER DEVICE SHIELD CONNECTED AT MODULE END ONLY Cable Connections to Field Devices 5 High Level Analog Output System - Voltage/Current Module GFK-0388G Analog Modules August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 58-5 Recommended Field Wiring Procedures The following procedures are recommended when connecting field wiring to the detachable terminal board on the Analog Output module. Module features referenced in the following procedures which are common to all IC697 I/O modules are illustrated in the following figure. Figure 6. I/O Module Common Features 1. Turn off power before removing or installing terminal boards. Open the hinged door on the module to access a jackscrew which holds the terminal board securely in place. The Detachable field wiring terminal board can now be removed from the module by turning the jackscrew counter-clockwise until it is fully disengaged. 2. To remove the terminal board, grasp the top of the terminal board and swing it outward. Caution Do not use the hinged door to remove the terminal board. The hinged door could be damaged if this is done. 3. The terminal board is designed to accept wire sizes from AWG #22 (0.36 mm2) through AWG #14 (2.10 mm2). It is important that when using AWG #14 (2.10 mm2) wire for wiring all points, that a maximum insulation diameter of .135 inch (3.43 mm) not be exceeded. To ensure proper connection, two wires may be terminated on any one terminal only if both wires are the same size. 4. The terminal board is designed to accept a maximum of (40) AWG #14 (2.10 mm2)wires. If AWG #14 (2.10 mm2) wires are to be used, then wire markers should be placed at least 8 inches (203 mm) from termination end to provide sufficient space for the hinged door to close. GFK-0388G High Level Analog Output System - Voltage/Current Module 6 Analog Modules August 1997 Series 90 -70 Programmable Controller Data Sheet Manual GFK-0600F 58-6

Need To Order A Specific Revision?

Give us a call at 1-800-360-6802 or 1-919-535-3180. We can help you with your Revision specific needs.


UPS Ground shipping is always FREE!


What is New Surplus?

These “New Surplus” units are a great cost saving alternative. This product is in the original manufacturer’s packaging with all sub-assemblies and documentation. Comes with a PDF Electric & Supply 3-year warranty.


UPS Ground shipping is always FREE!


What is Surplus New?

Surplus New - New unused and includes all sub-assemblies and documentation. Product may ship in manufacturer or PDF Electric & Supply packaging and includes a PDF Electric & Supply 3 Year Warranty.


UPS Ground shipping is always FREE!


What is Reconditioned?

Reconditioned products from PDF Electric & Supply are a cost-effective alternative to new and obsoleted PLC products. Every part is reconditioned down to the circuit board level. All parts are thoroughly inspected and hand-cleaned before being functionally tested in a fully configured system.


Our Reconditioned Products always come with a PDF Electric & Supply 2-Year Warranty.

UPS Ground shipping is always FREE!


110% PRICE MATCH GUARANTEE


We stand behind our prices with a 110% price match guarantee. If you buy a part from us and, within seven days of purchase, find that part advertised on an authorized distributor's website for less, simply contact us and give us a link to the lower advertised price and we'll refund you 110% of the difference between your purchase price and the advertised lower price. The part must be in-stock for immediate shipment and be in similar condition. All pricing must be displayed without signing in.

Repair Service


3-5 Days for most repairs. 24 hour repair upon request at no extra charge. If part is unrepairable, we will exchange with a working unit or return unrepaired.